Before you begin
All gas appliances require commissioning upon
installation toensure the appliance performs to specification and
minimise potential problems in the future. The CI units should function
correctly if the working supply pressure is set to specification.
Tools
Required:
A digital manometer is required to complete the
commissioning of this appliance.
Procedure
- Isolate the gas supply to the appliance
- Loosen the captive screw on the inlet test point directly
above the regulator
- Connect manometer to inlet test point on the gas inlet
pipe
- Turn on gas supply
- Operate the appliance and check the gas supply pressure
is correct for the gas type
- Adjust the gas supply via the regulator if required
- When the correct gas pressure has been set turn the appliance
off and isolate the gas supply. Remove manometer from the test point
and tighten screw.
- Turn on gas and check the test point for leakage with
soapy water.
- Isolate gas supply to appliance
- Loosen test point screw on burner (pictured) and connect
manometer to test point
- Turn on the gas supply
- Check the gas pressure is correct as per the data plate
on the bottom left corner of the appliance.
- Turn appliance off and isolate gas supply. Remove manometer
from test point and tighten screw.
- Turn on gas and check test point for leakage with soapy
water.
Results
If, after following the instructions above the unit is
not operating to specification, please contact Bosch Technical Service.