2. Specifications Previous topic Parent topic Child topic Next topic

Bosch reserves the right to change specifications without prior notice. The capacity may differ slightly, depending on the water pressure, water supply, piping conditions and water temperature.

ITEM SPECIFICATION
Model Number GWH10/13/16 -2 G..
AGA Approval Number 7456
Installation Indoor, Wall Mounted
Air supply/Exhaust Natural Draught
Ignition Hydrogenerator Electronic Ignition
Optimal Operating Water Pressure Range 200-1000 kPa
Minimum Operating Flow Rate 2.5 l/min
Dimensions & Weights 580mm(H) X 310mm(W) X 220mm(D) 10.2 kg
  655mm(H) X 350mm(W) X 220mm(D) 11.8 kg
  655mm(H) X 425mm(W) X 220mm(D) 13.7 kg
Connections 15mm Water Inlet
  NG 20mm Gas Inlet, LPG 15mm Gas Inlet
  15mm Water Outlet
Power Supply 3 VAC fromHydrogenerator
Safety Devices Flame Rod, Over temperature sensor, Flue Safety Device

Performance

ITEM PERFORMANCE
Technical Characteristics Units GWH10 GWH13 GWH16
Gas Consumption
Nominal Gas Consumption MJ 79 100NG 127
97LPG
Supply Pressure (operating pressure)
Natural Gas kPa 1.13 1.13 1.13
LPG (Butane/Propane) kPa 2.75 2.75 2.75
Number of injectors   12 14 16
Water Data
Maximum permissible Pressure kPa 1000 1000 1000
Temperature Selector in fully clockwise position
Temperature Rise °C 50 50 50
Flow Range l/min 2.5-4.6 2.5-6.2 2.5-8.6
Minimum operating water pressure kPa 35 35 50
Minimum water pressure for maximum flow kPa 50 60 80
Temperature Selector in fully clockwise position
Temperature Rise °C 25 25 25
Flow Range l/min 4-10 4-13 4-16
Minimum operating water pressure kPa 45 45 50